Products
IRRIGATION CONTROLLERS
SMALL SYSTEMS
PICCOLO 5 /ELEMENT 8
AFIK
METEOR
MEDIUM SYSTEMS
LARGE SYSTEMS
GREENHOUSES
FILTERS BACKFLUSHING CONTROLLERS
SPECIAL PURPOSE CONTROLLERS
WATER DISTRIBUTION CONTROL SYSTEM

METEOR

The METEOR is a powerful and professional irrigation controller, It has a unique user interface, allowing almost instant operation due to its simplicity. The user interface also allows translating this controller onto any language in very little time. The METEOR allows various combinations for its outputs and exist both in DC and AC versions.
METEOR
TYPE
O U T P U T S
I N P U T S
Main valve
Fert. pump
Stations
*
Filters
*
Alarm
Water meter
Fert. meter
Freeze contact
Emerg. contact
Tensio-meter
DP contact
**
AC
2 + 4
1
1
4
+
-
1
1
1
1
4
1
2 + 8
1
1
8
+
-
1
1
1
1
4
1
2+16
1
1
16
+
-
1
1
1
1
4
1
AC
3 + 3
1
2
3
+
-
1
2
1
1
2
1
3 + 7
1
2
7
+
-
1
2
1
1
2
1
3+15
1
2
15
+
-
1
2
1
1
2
1
DC
4 + 8
1
2
8
+
1
1
2
1
1
2
1
4+15
1
2
16
+
1
1
2
1
1
2
1

 
* Filters come in place of irrigation stations
** DP comes in place of tensiometers

SPESCIAL FERTIGATION FEATURES
  • Proportional fertigating: volume/volume or time/time.
  • Volumetric fertigating can be applied even when the injectors do not provide back indications.
  • Optimal distribution of the fertilizers during proportional fertigation. Uniformity is achieved by varying the interval between injections of fertilizers according to the water flow.
GENERAL FEATURES
  • Volumetric or time based irrigation.
  • Individual program per station.
  • Cyclic irrigation with intervals of 1-99 days.
  • Irrigation can be repeated 9999 times a day.
  • Sequential irrigation.
  • Irrigation by tensiometers.
  • Ability to change quantities left any time.
  • Volumetric or time based fertigation.
  • Fertilizing in three stages: pre-watering, fertilization and post-watering.
  • Handling various ratios of water and fertilizer meters.
  • Delayed or advanced action of the main valve.
  • Data unaffected by power down situations.
  • Low energy consumption of the DC models.
  • Filters flushing triggered by DP and/or by time.
  • Dosage completing of interrupted programs.
  • Manual system freeze and manual start/stop of programs.
  • Emergency program to be used in case of extreme temperatures.

FAULTS DETECTION

  • High flow and Low flow.
  • Water and fertilizer leakages.
  • Low pressure.
  • Failures in fertilizer reading.
  • Faulty tensiometers causing endless irrigations.
  • Endless backflushing caused by faulty DP sensor.
  • Short circuited solenoids.
REPORTS
  • Last flow and current flow.
  • Remaining quantities for all parameters.
  • Current system status.
  • Current status per valve.
  • Display of active outputs.
  • Status of inputs.

PDF Download – Brochure:

English
Spanish